{"id":8060,"date":"2026-09-07T13:58:09","date_gmt":"2026-09-07T11:58:09","guid":{"rendered":"https:\/\/bf-engineering.com\/?post_type=produkt&#038;p=8060"},"modified":"2026-09-07T17:05:29","modified_gmt":"2026-09-07T15:05:29","slug":"kipp-zonen-cm4-high-temperature-pyranometer","status":"publish","type":"produkt","link":"https:\/\/bf-engineering.com\/en\/product\/kipp-zonen-cm4-high-temperature-pyranometer\/","title":{"rendered":"Kipp &#038; Zonen CM4 \u2013 High-Temperature Pyranometer"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"author":7,"featured_media":8064,"menu_order":14,"template":"","meta":{"_acf_changed":false,"footnotes":""},"anwendung-kat":[],"produkt-kat":[99],"class_list":["post-8060","produkt","type-produkt","status-publish","has-post-thumbnail","hentry","produkt-kat-measurement-equipment","no-featured-image-padding"],"acf":{"cpt-modules":{"":null,"description":"The Kipp &amp; Zonen CM4 is a specialized high-temperature pyranometer for measuring irradiance in W\/m\u00b2 under extreme thermal conditions.\r\n\r\nWith an operating temperature range of \u221240 to +150 \u00b0C, the CM4 is particularly suitable for climate chambers, solar simulation systems, environmental test benches and industrial testing laboratories. This allows irradiance to be measured directly under the actual temperature conditions of a test.\r\n\r\nThe broad spectral range of 300 to 2,800 nm and a maximum irradiance of 4,000 W\/m\u00b2 make the CM4 particularly suitable for combined temperature and irradiance testing in automotive testing, material testing and environmental simulation.\r\n\r\n<strong>Highlights<\/strong>\r\n<ul>\r\n \t<li>High-temperature pyranometer up to +150 \u00b0C<\/li>\r\n \t<li>Irradiance up to 4,000 W\/m\u00b2<\/li>\r\n \t<li>Spectral range 300\u20132,800 nm<\/li>\r\n \t<li>Analog output 0\u201340 mV<\/li>\r\n \t<li>Integrated Pt100 temperature sensor<\/li>\r\n \t<li>10 m high-temperature signal cable<\/li>\r\n \t<li>ISO 9060:2018 Spectrally Flat Class C<\/li>\r\n \t<li>Ideal for climate chambers and solar simulation<\/li>\r\n<\/ul>","button":[{"link":{"title":"Data sheet Kipp & Zonen CM4","url":"https:\/\/cdn.hach.com\/1XMCM0ZF\/at\/vb49s3ksn8pp388w5sh4rb\/KippZonen_Manual_Pyranometer_CM4_V1007.pdf","target":"_blank"},"label":"datasheet","style":"secondary","type":"download"}],"text":{"title":"","description":"","button":null},"gallery":"","references":"","tabs":[{"title":"Technical Data","description":"<table style=\"height: 407px;\" width=\"566\">\r\n<thead>\r\n<tr>\r\n<th style=\"text-align: left;\"><strong>Measured quantity:<\/strong><\/th>\r\n<th style=\"text-align: left;\">Irradiance<\/th>\r\n<\/tr>\r\n<\/thead>\r\n<tbody>\r\n<tr>\r\n<td><strong>Unit:<\/strong><\/td>\r\n<td>W\/m\u00b2<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Measurement principle:<\/strong><\/td>\r\n<td>Thermopile pyranometer<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Classification:<\/strong><\/td>\r\n<td>ISO 9060:2018 Spectrally Flat Class C<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Spectral range:<\/strong><\/td>\r\n<td>300\u20132,800 nm<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Maximum irradiance:<\/strong><\/td>\r\n<td>4,000 W\/m\u00b2<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Analog output:<\/strong><\/td>\r\n<td>0\u201340 mV<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Response time:<\/strong><\/td>\r\n<td>&lt; 8 s at 95 %<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Operating temperature:<\/strong><\/td>\r\n<td>\u221240 to +150 \u00b0C<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Temperature measurement:<\/strong><\/td>\r\n<td>Integrated Pt100 temperature sensor<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Field of view:<\/strong><\/td>\r\n<td>180\u00b0<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Protection rating:<\/strong><\/td>\r\n<td>IP67<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Cable length:<\/strong><\/td>\r\n<td>10 m high-temperature signal cable<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n&nbsp;\r\n\r\nThe CM4 was specifically developed for measurements where conventional pyranometers cannot be used due to high ambient temperatures.","button":null,"image":"","tables":null},{"title":"Applications","description":"The CM4 is particularly suitable for measuring irradiance at high temperatures.\r\n\r\nTypical applications include:\r\n<ul>\r\n \t<li>Climate chambers<\/li>\r\n \t<li>Solar simulation chambers<\/li>\r\n \t<li>Environmental test benches<\/li>\r\n \t<li>Automotive testing<\/li>\r\n \t<li>Complete vehicle testing<\/li>\r\n \t<li>Component testing<\/li>\r\n \t<li>Interior and exterior testing<\/li>\r\n \t<li>Material testing<\/li>\r\n \t<li>Thermal load testing<\/li>\r\n \t<li>Research &amp; Development<\/li>\r\n<\/ul>\r\nThanks to its temperature resistance up to +150 \u00b0C, the sensor can be positioned directly inside the test chamber and at the same height as the test specimen.","button":null,"image":"","tables":null},{"title":"Irradiance Measurement","description":"The CM4 measures the actual irradiance reaching a surface in watts per square meter (W\/m\u00b2).\r\n\r\nThis makes it possible to verify the actual radiation power reaching the test specimen under real test conditions.\r\n\r\n<strong>Typical measurement tasks include:<\/strong>\r\n<ul>\r\n \t<li>Measuring irradiance<\/li>\r\n \t<li>Measuring radiation power in W\/m\u00b2<\/li>\r\n \t<li>Measuring artificial solar radiation<\/li>\r\n \t<li>Recording irradiance distribution<\/li>\r\n \t<li>Verifying test conditions<\/li>\r\n \t<li>Reference and comparative measurements<\/li>\r\n \t<li>Homogeneity measurements<\/li>\r\n<\/ul>\r\nThe integrated Pt100 also enables measurement of the sensor temperature, allowing for improved evaluation of the measurement conditions.","button":null,"image":"","tables":null},{"title":"Solar Simulation & Testing","description":"The CM4 is particularly suitable for solar simulation tests at elevated temperatures.\r\n\r\nTypical test specimens include vehicles, cockpits, instrument panels, displays, electronics, plastics, paints, coatings and other technical components.\r\n\r\nFor homogeneity measurements of a solar simulator, irradiance can be measured at several defined positions across the test area.\r\n\r\nThis makes it possible to determine the minimum, maximum and average irradiance as well as local deviations across the test area.","button":null,"image":"","tables":null},{"title":"Integration","description":"The CM4 can be used as a standalone sensor or as part of a complete irradiance measurement system.\r\n\r\n<strong>Possible components include:<\/strong>\r\n<ul>\r\n \t<li>CM4 high-temperature pyranometer<\/li>\r\n \t<li>Measuring amplifier<\/li>\r\n \t<li>Data logger<\/li>\r\n \t<li>DAQ system<\/li>\r\n \t<li>Temperature measurement<\/li>\r\n \t<li>Evaluation software<\/li>\r\n \t<li>Automated measurement systems<\/li>\r\n<\/ul>\r\nBF Engineering supports the integration of suitable irradiance measurement technology into climate chambers, solar simulation systems and industrial test benches.\r\n\r\nIn addition to integrating the measurement technology, BF Engineering can also perform measurements, homogeneity testing and calibration of solar simulation systems and irradiance test benches on request.","button":null,"image":"","tables":null}]},"variants":{"toggle":false,"names":[{"title":""},{"title":""},{"title":""},{"title":""}]},"shop-link":"","is_produkt":true,"contact-person_selection":""},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Kipp &amp; Zonen CM4 \u2013 High-Temperature Pyranometer | BF Engineering<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/bf-engineering.com\/en\/product\/kipp-zonen-cm4-high-temperature-pyranometer\/\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/bf-engineering.com\\\/en\\\/product\\\/kipp-zonen-cm4-high-temperature-pyranometer\\\/\",\"url\":\"https:\\\/\\\/bf-engineering.com\\\/en\\\/product\\\/kipp-zonen-cm4-high-temperature-pyranometer\\\/\",\"name\":\"Kipp & Zonen CM4 \u2013 High-Temperature Pyranometer | BF Engineering\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bf-engineering.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/bf-engineering.com\\\/en\\\/product\\\/kipp-zonen-cm4-high-temperature-pyranometer\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/bf-engineering.com\\\/en\\\/product\\\/kipp-zonen-cm4-high-temperature-pyranometer\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bf-engineering.com\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2026\\\/09\\\/ChatGPT-Image-7.-Sept.-2026-13_32_32.png\",\"datePublished\":\"2026-09-07T11:58:09+00:00\",\"dateModified\":\"2026-09-07T15:05:29+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/bf-engineering.com\\\/en\\\/product\\\/kipp-zonen-cm4-high-temperature-pyranometer\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/bf-engineering.com\\\/en\\\/product\\\/kipp-zonen-cm4-high-temperature-pyranometer\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bf-engineering.com\\\/en\\\/product\\\/kipp-zonen-cm4-high-temperature-pyranometer\\\/#primaryimage\",\"url\":\"https:\\\/\\\/bf-engineering.com\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2026\\\/09\\\/ChatGPT-Image-7.-Sept.-2026-13_32_32.png\",\"contentUrl\":\"https:\\\/\\\/bf-engineering.com\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2026\\\/09\\\/ChatGPT-Image-7.-Sept.-2026-13_32_32.png\",\"width\":1254,\"height\":1254},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/bf-engineering.com\\\/en\\\/product\\\/kipp-zonen-cm4-high-temperature-pyranometer\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/bf-engineering.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\\\/\\\/bf-engineering.com\\\/en\\\/product\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Measurement equipment\",\"item\":\"https:\\\/\\\/bf-engineering.com\\\/en\\\/product\\\/category\\\/measurement-equipment\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Kipp &#038; Zonen CM4 \u2013 High-Temperature Pyranometer\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/bf-engineering.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/bf-engineering.com\\\/en\\\/\",\"name\":\"BF Engineering\",\"description\":\"Engineering the Sun\",\"publisher\":{\"@id\":\"https:\\\/\\\/bf-engineering.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/bf-engineering.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/bf-engineering.com\\\/en\\\/#organization\",\"name\":\"BF Engineering\",\"url\":\"https:\\\/\\\/bf-engineering.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bf-engineering.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/bf-engineering.com\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2026\\\/06\\\/logo_bf-engineering.svg\",\"contentUrl\":\"https:\\\/\\\/bf-engineering.com\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2026\\\/06\\\/logo_bf-engineering.svg\",\"caption\":\"BF Engineering\"},\"image\":{\"@id\":\"https:\\\/\\\/bf-engineering.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Kipp & Zonen CM4 \u2013 High-Temperature Pyranometer | BF Engineering","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/bf-engineering.com\/en\/product\/kipp-zonen-cm4-high-temperature-pyranometer\/","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/bf-engineering.com\/en\/product\/kipp-zonen-cm4-high-temperature-pyranometer\/","url":"https:\/\/bf-engineering.com\/en\/product\/kipp-zonen-cm4-high-temperature-pyranometer\/","name":"Kipp & Zonen CM4 \u2013 High-Temperature Pyranometer | BF Engineering","isPartOf":{"@id":"https:\/\/bf-engineering.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bf-engineering.com\/en\/product\/kipp-zonen-cm4-high-temperature-pyranometer\/#primaryimage"},"image":{"@id":"https:\/\/bf-engineering.com\/en\/product\/kipp-zonen-cm4-high-temperature-pyranometer\/#primaryimage"},"thumbnailUrl":"https:\/\/bf-engineering.com\/wp-content\/uploads\/sites\/2\/2026\/09\/ChatGPT-Image-7.-Sept.-2026-13_32_32.png","datePublished":"2026-09-07T11:58:09+00:00","dateModified":"2026-09-07T15:05:29+00:00","breadcrumb":{"@id":"https:\/\/bf-engineering.com\/en\/product\/kipp-zonen-cm4-high-temperature-pyranometer\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bf-engineering.com\/en\/product\/kipp-zonen-cm4-high-temperature-pyranometer\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bf-engineering.com\/en\/product\/kipp-zonen-cm4-high-temperature-pyranometer\/#primaryimage","url":"https:\/\/bf-engineering.com\/wp-content\/uploads\/sites\/2\/2026\/09\/ChatGPT-Image-7.-Sept.-2026-13_32_32.png","contentUrl":"https:\/\/bf-engineering.com\/wp-content\/uploads\/sites\/2\/2026\/09\/ChatGPT-Image-7.-Sept.-2026-13_32_32.png","width":1254,"height":1254},{"@type":"BreadcrumbList","@id":"https:\/\/bf-engineering.com\/en\/product\/kipp-zonen-cm4-high-temperature-pyranometer\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/bf-engineering.com\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/bf-engineering.com\/en\/product\/"},{"@type":"ListItem","position":3,"name":"Measurement equipment","item":"https:\/\/bf-engineering.com\/en\/product\/category\/measurement-equipment\/"},{"@type":"ListItem","position":4,"name":"Kipp &#038; Zonen CM4 \u2013 High-Temperature Pyranometer"}]},{"@type":"WebSite","@id":"https:\/\/bf-engineering.com\/en\/#website","url":"https:\/\/bf-engineering.com\/en\/","name":"BF Engineering","description":"Engineering the Sun","publisher":{"@id":"https:\/\/bf-engineering.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bf-engineering.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/bf-engineering.com\/en\/#organization","name":"BF Engineering","url":"https:\/\/bf-engineering.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bf-engineering.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/bf-engineering.com\/wp-content\/uploads\/sites\/2\/2026\/06\/logo_bf-engineering.svg","contentUrl":"https:\/\/bf-engineering.com\/wp-content\/uploads\/sites\/2\/2026\/06\/logo_bf-engineering.svg","caption":"BF Engineering"},"image":{"@id":"https:\/\/bf-engineering.com\/en\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/bf-engineering.com\/en\/wp-json\/wp\/v2\/produkt\/8060","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bf-engineering.com\/en\/wp-json\/wp\/v2\/produkt"}],"about":[{"href":"https:\/\/bf-engineering.com\/en\/wp-json\/wp\/v2\/types\/produkt"}],"author":[{"embeddable":true,"href":"https:\/\/bf-engineering.com\/en\/wp-json\/wp\/v2\/users\/7"}],"version-history":[{"count":4,"href":"https:\/\/bf-engineering.com\/en\/wp-json\/wp\/v2\/produkt\/8060\/revisions"}],"predecessor-version":[{"id":8133,"href":"https:\/\/bf-engineering.com\/en\/wp-json\/wp\/v2\/produkt\/8060\/revisions\/8133"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bf-engineering.com\/en\/wp-json\/wp\/v2\/media\/8064"}],"wp:attachment":[{"href":"https:\/\/bf-engineering.com\/en\/wp-json\/wp\/v2\/media?parent=8060"}],"wp:term":[{"taxonomy":"anwendung-kat","embeddable":true,"href":"https:\/\/bf-engineering.com\/en\/wp-json\/wp\/v2\/anwendung-kat?post=8060"},{"taxonomy":"produkt-kat","embeddable":true,"href":"https:\/\/bf-engineering.com\/en\/wp-json\/wp\/v2\/produkt-kat?post=8060"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}